The Lifepak 9 is defibrillator/monitor, cardioscope and non-invasive pacemaker. It provides 17 energy selections, heart rate alarms, three-lead ECG monitoring, recorder and Code Summary critical event recorder. The microprocessor-based Lifepak 9 includes an internal battery supply and is available with optional pediatric paddles, internal paddles, pacing cable and pads, and ECG patient cable and leads.
ECG Monitor Features: • ECG Lead Selections: STD, Paddles, I, II, III • Input: Isolated ECG via Quick-Look® defibrillator paddles, Fast-Patch® disposable defibrillation/ ECG electrodes or three-lead patient cable. • Patient Cable Length: 13-foot total length (10-foot w/ three-foot leads) • Common Mode Rejection: 100dB min. with respect to chassis ground and 65dB min. with respect isolated ground, when measured at 60Hz (common mode range for patient cable input is 10 Volts peak w/ respect to isolated ground) • Monitor Display Size: 4” (w) x 3” (h) • Sweep Speed: 25 mm/sec • Frequency Response: Non-diagnostic • ECG Leads: 1.0 to 40Hz (-3dB) • Paddles: 2.2 to 20 Hz (-3dB) • ECG Size: Adjusts amplitude of ECG trace on monitor and strip chart recorder • Heart Rate Meter: Three-digit readout displays rates from 20 to 300 bpm; heart rates outside this range do not yield valid systole tones or heart rate display • Heart Rate Alarm: User selectable alarm limits with three high/low settings (150/40, 120/60, 160/90 — other limit options are available via set up menu); 1 mV Cal: Momentary push button switch on rear panel simulates a 1 mV signal pulse to the ECG input.
Defibrillator Specifications: Energy Selection • External Paddles 1,2,3,4,5,6,7,8,9,10,20,30,50,100,200,300,360J • Internal Paddles 1,2,3,4,5,6,7,8,9,10,20,30,50J • Charge Controls - Independent momentary push-button controls on front panel and APEX paddle • Paddle Cord Length - 10 feet (3 m) • Charge Time - Charge to 360J in less than 10 s with a fully-charged battery • Defibrillator Energy - ±15% at 50Ω • Accuracy - ±30% over the range of 25 to 100Ω • Defibrillator Waveform - 5ms monophasic pulse General Specifications:
• AC Input Options - 120 to 240VAC nominal line voltage adjustment. 50 or 60 Hz with adjustment in Setup Menu. • Battery Type - Sealed lead-acid, 16 Vdc nominal, 3Ahr • Battery Capacity (A new, fully-charged battery will provide one of the following prior to shutdown): - Number of 360J discharges Typical: 75 | Minimum: 40 - Minutes of monitoring Typical: 90 | Minimum: 70 • Low Battery Indicator: - Number of 360J discharges before warning Typical: 50 | Minimum: 20 - Minutes of monitoring Typical: 90 | Minimum: 70 • Battery Charge Time - 24 hours to full capacity • Power Consumption - 160W • Size - 13.9” h x 11.7” w x 12.2” d (35.2 cm h x 29.7 cm w x 31.0 cm d) • Weight - 28 lbs (12.7 kg) • Standard Paddle Electrode Area - 82cm²
|